How To Remove and Reinstall The rEvodream
On more recent rEvodreams, this is clearly marked with a Shrinkwrap band around the cable gland
Tools Needed
- Allenhead key: 3 mm (mini / Standard)
- Allenhead key: 2.5 mm (micro)
- Allenhead key: 2 mm
- Wrench 7 and 15 mm
- (needle nose plyers)
Steps:
1: Unscrew the 2 upper screws that attach the pressure gauge to the rEvodream
2: Take away the hose protector opening the Velcro
3: Remove the HUD from its fixing plate
4: Remove the cover plate of the triple entry port.
5: Unscrew the clamping part of the cable gland first: this is the right part of the cable gland!
It is important to first unscrew the right part, while the left part stays fixed, if not the cable can twist!
6: Loosen the cable of the rEvodream where it attaches to the sensors (rEvodream NG / P) or unplug the wet connector for rEvodream P5
7: Now gently slide the cable back through the triple connector and the PG7 thread and the rEvodream is completely free.
8: When installing the rEvodream again, do this procedure in the opposite order: the left part of the cable gland can be tightened with a flat key (remember, plastic, so do not over tighten), the clamping part itself (the right part) must be hand tightened to max, and then only ¼ turn with a key. If you tighten the clamp completely with a key, you will damage the cable.
Remark:
The cable entry into the rEvodream housing can be sealed with a PG7 plug.
The wet connector can be capped of with a blanking plug (rEvodream P5)
For further information or if you need extra help, please contact your local instructor or service center.